Proximal edge dissection
WebbCompared to stents without edge dissection, stents with edge dissection had a higher stent expansion (1.507±0.445 vs. 1.174±0.265, P=0.0072) and a trend of higher axial stent symmetry (0.821±0.051 vs. 0.758±0.100, P=0.0727).There were no significant difference in maximal stent diameter, minimal stent diameter, stent symmetry, maximal stent area … WebbProximal stent edge dissection detected by OCT OCT showed that although the dissection was within intima, the maximal arc was 95.7 degrees and longitudinal length was 3.4mm (Figure 3). The findings met the criteria for major dissection, therefore we considered an additional stent implantation (1,2).
Proximal edge dissection
Did you know?
Webb9 okt. 2024 · Regarding stent edge findings, the presence of any stent edge dissection immediately after percutaneous coronary intervention was also similar between the groups (25% vs. 15%, respectively; p = 0.30) and most stent edge dissections resolved completely within 3 months, regardless of location or dissection severity. Webb1 aug. 2013 · Stent edges were defined as the 5-mm regions immediately adjacent to the stent borders, both distally and proximally. Edge dissection was defined as disruptions …
Webb4 nov. 2024 · Stent edge dissection (SED) is a well-known predictor of worse clinical outcomes. However, impact of SED after current-generation drug-eluting stent (DES) … Webb8 juni 2024 · Every additional millimeter of metal that has to go into the arteries comes with its own risks and benefits. Whether it has to go in for a dissection or to fix a blockage doesn’t really matter. Most interventionalists will try their best to minimize stent use to avoid putting metal into the artery unless they absolutely NEED to have it. So ...
Webb24 feb. 2024 · Stent implantation for the treatment of coronary artery disease can cause unintended tearing at of vessel wall adjacent to the stent struts resulting in a stent edge … Webb6 apr. 2024 · ObjectiveType A aortic dissection (TAAD) is associated with high morbidity and mortality, and open surgery is the best treatment option. Development of endovascular repair devices for TAAD will benefit patients deemed unfit for open surgery. In this study, we performed a thorough investigation of anatomical features in Asian patients with …
Webb19 okt. 2024 · Proximal edge dissection (n = 40) was more frequent than distal (n = 32), with similar findings of maximal flap opening, maximal flap length, longitudinal flap …
Classification of stent edge dissection. Based on the depth of dissection, stent edge dissection is categorized as intimal or medial. Left, intimal dissection is observed in the reference segment. The angle of the flap (arrow) is 34 degrees, and the effective lumen area (gray area) within the dissection flap is 5.09 mm 2. pipefy transfer pipe between orgsWebb15 juli 2011 · In the proximal edge only one dissection was detected by angiography while OCT detected 7. In the distal edge angiography and OCT agreed in the detection of 7 … pipefy playgroundWebbDeployment of a Promus Premier 3.0/12 mm stent in the proximal RCA overlapping with proximal edge of the previously placed stent. 10 of 13. 10 of 13. Post-dilation of the stents placed in the RCA with a Trek 3. ... procedure was complicated by a minor flow-limiting, Type E distal stent edge dissection. IC vasodilators were given with no change ... pipefy rhWebb1 sep. 2024 · OCT helped to define the precise extent and clinical significance of stent edge dissection, proximal and distal reference vessel diameter and prevent iatrogenic … pipefy was ist dasWebb1 okt. 2024 · I77.79 is a billable/specific ICD-10-CM code that can be used to indicate a diagnosis for reimbursement purposes. The 2024 edition of ICD-10-CM I77.79 became effective on October 1, 2024. This is the American ICD-10-CM version of I77.79 - other international versions of ICD-10 I77.79 may differ. pipefy leadsWebbAn additional stent implantation may be considered for a major edge dissection, especially if it is associated with an intra-dissection lumen 90% of the respective proximal or distal … pipefy templatessteph passes ray allen